YKS710 7000kW 6kV High Voltage Squirrel-Cage Induction Motor, YYKK/YKS Series


                    
Category :

Basic Info

ItemParameterItemParameter
Model NO.YKS710-4-7000KW-6KVNumber of StatorThree-Phase
Rotor StructureSquirrel-CageCasing TypeClosed Type
Number of Poles2p–16pStarting ModeDirect on-line Starting
CertificationISO9001, CCC, CERated Powerup to 25000kW
Frequency50Hz/60HzVoltage6kV, 6.6kV, 10kV, 11kV, 13.2kV, 13.8kV
Protection GradeIP54Cooling MethodIC81W
Mounting ArrangementIMB3Rotation DirectionBoth Directions
Insulation ClassFColorCustomizable
Duty TypeS1Design StandardIEC
Temperature Rise ClassBMax Ambient Temperature40℃
Altitude≤1000m above sea levelBearingSKF Bearing
Transport PackageStandard Seaworthy PackingBrandCHANGLI
OriginChinaHS Code8501530090
Production Capacity500000 sets per year——

Product Description

Y, YKS, YQF, YKK, YR, YRKS, YRQF and YRKK series high voltage three-phase induction motors were developed and launched by our company since the 1980s, with more than 30 years of development history. In recent years, upgraded insulation materials, low-loss silicon steel sheets, higher performance grades and optimized design schemes effectively cut motor losses and boost power capacity. Drawing on our 60-year experience in high voltage induction motor design and manufacturing, we have completed the latest round of optimization to meet domestic and industrial market demands. Test results confirm that this new series reaches or approaches the world’s advanced level in both technical and economic performance.

These motors are mass-produced and exported to over 20 countries and regions including Europe, America, Africa, Hong Kong and Macao, as well as widely supplied across mainland China, earning consistent positive feedback from end users.

Manufactured with premium raw materials and mature production processes, the series features high efficiency, energy saving, low vibration, stable operation and easy installation & maintenance.

Its power ratings, electrical characteristics, mounting dimensions and tolerances comply with GB755 (Rotating electrical machines – Ratings and performance), IEC 60034-1 and relevant machinery industry standards.

In accordance with GB4942.1 and IEC 60034-5, the enclosure protection grades cover IP23, IP44, IP54, IP55 and IP56. IP23 motors can be modified to IP44 (pipe ventilation) or IPW24 (weather-protected type). Custom protection classes are available upon request.

Cooling options follow GB/T1993 and IEC 60034-6, including IC01, IC611 and IC81W. Other cooling configurations can be supplied as required.

The standard construction and mounting form is IMB3 (horizontal foot-mounted), conforming to GB997 and IEC 60034-7.

Based on rotor type, protection grade and cooling method, the series is divided into 8 sub-models:

ModelProtection ClassCooling MethodSquirrel Cage RotorWound Rotor
Damp ProofIP23IC01Y SeriesYR Series
Weather ProtectedIPW24IC01YQF SeriesYRQF Series
Air-Water Cooled EnclosedIP44, IP54, IP55, IP56IC81WYKS SeriesYRKS Series
Air-Air Cooled EnclosedIP44, IP54, IP55, IP56IC611YKK SeriesYRKK Series

All technical data and external installation dimensions of 10kV motors in this range can be adapted for 3kV, 10.5kV and 11kV variants of the same frame sizes.

Application

This series drives general machinery such as compressors, fans, water pumps, feeders and conveyors, serving as prime movers for mines, machinery plants, petrochemical facilities, power plants and other industrial & mining sites.

For heavy inertia loads including blowers, coal mills, rolling mills, crushers and belt conveyors, customers need to provide complete technical data and sign a technical agreement with us. This supports customized design and guarantees reliable motor operation.

Normal Operating Conditions

  • Altitude: ≤1000m above sea level
  • Max ambient temperature: ≤40℃
  • Minimum ambient temperature: -15℃ for rolling bearing motors; 5℃ for sliding bearing motors; YKS & YRKS series minimum ambient temperature 5℃
  • YKS / YRKS cooling inlet water: max 33℃, min 5℃
  • Humidity condition: average monthly maximum relative humidity ≤90% with average monthly minimum temperature ≤25℃ in the wettest month
  • Power frequency: 50Hz ±1%
  • Supply voltage deviation: within ±5% of rated voltage
  • Duty: S1 continuous running

Construction Description

Y and YR are base models with IP23 protection and IC01 cooling. Derivative types include YKS (air-water cooled), YQF (weather protected), YKK (air-air cooled), YRKS, YRQF and YRKK.

The motor adopts a widely accepted box-type structure. Frame and end shields are steel plate welded for high rigidity and low weight. Removing the cooler or protective cover allows direct inspection and access to internal components, simplifying installation and maintenance.

The stator adopts an external pressing structure. Stator windings use Class F insulation and anti-corona materials. Winding terminals are fixed with special reliable binding technology. The whole stator undergoes VPI vacuum pressure impregnation with Class F solventless varnish for outstanding insulation, moisture resistance and surge withstand capability.

Squirrel cage rotors are mostly cast aluminum type with proven anti-fracture performance for stable operation. Copper bar squirrel cage rotors use advanced reliable welding and slot fastening technology. Wound rotors are fitted with Class F insulation and processed by VPI impregnation.

Two bearing types are available: rolling bearing and sliding bearing, selected according to motor power and speed. Base bearing protection grade is IP44; bearing protection will be upgraded together with higher motor enclosure grade.

Rolling bearing versions are equipped with on-line grease filling and draining ports, supporting greasing without shutdown via dedicated tools.

The main terminal box is sealed to IP54. It is fitted on the right side (viewed from shaft extension), and can be relocated to the left side per customer request. Cable entry direction can be adjusted to top, bottom, left or right. Independent grounding terminals are built inside the box.

Starting Instruction for Y / YKS / YQF / YKK Induction Motors

Advanced computer simulation is applied to calculate temperature and stress distribution of squirrel cage rotors, preventing premature damage caused by overload during startup. Please comply with the following requirements:

  • Moment of inertia (referred to motor speed) of driven equipment shall not exceed the allowable load J value listed in technical datasheet
  • Terminal voltage at motor terminals during starting shall not be lower than 85% of rated voltage
  • Load torque characteristic matches typical pump and fan curve

Under above conditions, the motor allows two successive cold starts or one hot start, with natural coast-down between attempts. Any further restart requires a 1-hour waiting period.

If the load inertia exceeds the listed J value, frequent starting is needed, or heavy-load startup is required, contact our engineering team for custom design confirmation to secure reliable startup performance.

Certifications

ISO9001, CCC, CE

Packaging & Shipping

Power range: 0.55kW ~ 20000kW
Voltage range: 380V ~ 13.8kV
Frame size: 80mm–1120mm

Our Advantages

  • Broad available power range
  • Superior starting performance
  • Suitable for diverse industries and global projects
  • High reliability to cut downtime and operating cost
  • Flexible customized design available
  • FAT witness test: on-site or online witnessing supported

Quality Control

All measuring instruments are calibrated annually. Full inspection covers every component:

PartInspection Items
Coil1. Raw material physical & chemical test2. Winding process audit3. Winding dimension check
Iron Core1. Silicon steel sheet material test report2. Lamination burr & coating inspection3. Stack dimension verification
Frame1. Weld qualification document2. Finishing dimensional inspection
Rotor1. Core stacking inspection2. Conductor bar welding check3. Bar & end ring material, appearance, conductivity & dimension test4. Slot bar fastening inspection5. Core outer diameter & overall dimension check6. Dynamic balancing correction
Shaft1. Raw material and annealing inspection2. Finishing check
Stator1. Core compression check2. Core length and segment length inspection3. Winding insertion check4. Core loss test
Assembly1. Plain bearing dimension and surface quality2. Air gap, stator-rotor center alignment, internal fan & shroud clearance3. Internal cleaning check4. Shaft center height and mounting dimension
Test1. Routine test2. Type test

Test Items

Every motor is fully tested before delivery and shipped with an official test report only after passing.

  • Routine Test: Winding DC resistance, insulation resistance to earth, high-pot withstand test, no-load current, no-load power & loss, three-phase current unbalance, locked rotor current, locked rotor torque, maximum torque, rotation direction, vibration (horizontal / vertical / axial), noise
  • Type Test: Full-load input power, full-load current, stator copper loss, rotor loss, iron loss, mechanical loss, stray loss, slip, stator winding temperature rise, bearing temperature, hot insulation resistance, overload test, power factor, efficiency

After Sales Service

Warranty Terms

Standard warranty: 12 months from commissioning OR 18 months from delivery, whichever comes first. Extended warranty is available upon separate negotiation.


0
Inquire for more cooperation or product information.
We will contact you within 1 working day, please check your email.
YKS710 7000kW 6kV High Voltage Squirrel-Cage Induction Motor, YYKK/YKS Series
Company Name
Name
Mail
Mobile phone
Message
Send

Weigao

We reply immediately
Welcome to our website. Ask us anything 🎉

Start Chat with: